Chubb Zonemaster 108 Manual

Chubb Zonemaster 108 Manual 9,9/10 2247votes

Read (GB4395)FPS138.pdf text version The Chubb Zonemaster 100 range of conventional fire alarm panels provide a versatile and effective method of fire protection control. Suitable for small to medium sized commercial and industrial premises. Zonemaster 100 Conventional Fire Control Equipment FIRE DETECTION PRODUCT RANGE s Compatible with a wide range of conventional detection devices 2, 4, 8, 12, 16 & 24 zone options Keyswitch security prevents unauthorised use One man walk testing for simple servicing Latching or non-latching zone flexibility Complies with BS5839 Pt4 Covering 2, 4, 8, 12, 16 and 24 zones of detection the Chubb Zonemaster 100 range of control panels have been designed to be easy to use, robust and secure. To ensure continuous, reliable operation, Zonemaster monitors the wiring to the detection devices, manual call points and fire alarm sounders. Zonemaster panels can be linked to a Chubb Alarm Receiving Centre (ARC).

This will provide 24 hour remote monitoring ensuring a rapid response to fire or fault conditions. In the event of a mains failure back-up batteries which are housed inside the Zonemaster cabinet will continue to power the system. The Zonemaster 100 range is compatible with the Chubb Fireseeker range of conventional detection devices in addition to a wide range of other manufacturers detectors, making an ideal choice when upgrading existing fire systems. Designed to comply with British Standards BS5839 Pt 4, 1988; all control panels are engineered from high quality steel, with pre-formed 20mm knockouts located on the top of the enclosure for cable access.

Read and Download Chubb Zonemaster 108 Manual Free Ebooks in PDF format - MARINE NET COURSE ANSWERS NELSON FUNCTIONS 11 SOLUTIONS CHAPTER 3 ELEMENTS OF. Chubb Zonemaster 108 Manual Read (GB4395)FPS138. Hyster 45 Manual. pdf - Readbag The Chubb Zonemaster 100 range of conventional fire alarm panels provide a versatile and. Of Chubb Zonemaster 108 Manual. This is committed to provide the most applicable as well as related pdf This is committed to provide the most applicable as well as related pdf within our data bank on your desirable subject.

Chubb Zonemaster 108 ManualChubb Zonemaster 108 Manual

The Zonemaster range is ideal for small to medium sized commercial and industrial premises such as guesthouses, high street shops and light industrial units. S s s s s Making Your World a Safer Place TECHNICAL DATA Power Input Voltage (VAC) System Voltage (VDC) Max Battery Size (A/H) Zonemaster Zonemaster Zonemaster Zonemaster Zonemaster Zonemaster 102 104 108 112 116 124 230 V, 50Hz 24 7 12 Zonemaster Zonemaster Zonemaster Zonemaster Zonemaster Zonemaster 102 104 108 112 116 124 Current Consumption Panel Quiescent (ma) Full Alarm Current (ma) Detection Zone Quiescent (ma) 100 210 130 280 170 410 1.6 200 550 220 780 312 1020 Outputs Number of Sounder Circuits Max.

Read FPS138 Zonemaster 100 text version Chubb Fire Chubb Zonemaster 100A & AT Fire Systems Prevent Fire Detect Fire Contain Fire Escape Fire Product Zonemaster 100A & AT Conventional Fire Control Equipment System Benefits The Chubb Zonemaster 100A & AT range of conventional alarm panels provides a versitile and effective method of fire protection control. Compatible with a wide range of conventional detection devices the Zonemaster range is ideal for small to medium sized commercial and industrial premises such as guesthouses, high street shops and light industrial units. High standards of build quality and performance Designed to comply with European Standards EN54 (parts 2 & 4). Professionally finished All control panels are engineered from high quality steel, with pre-formed 20mm knockouts located on the top and in the back of the enclosure for cable access.

New Home Sewing Machine Model 108 Manual

Flexible coverage Range consists of 2, 4 and 8 zone control panels. Panels are available as either standard or two wire.

Chubb Zonemaster 108 Manual

Zonemaster 100A - Detectors and call points are wired on separate circuits to sounders. Zonemaster 100AT - Detectors, call points and sounders are wired on the same pair of cables Reliable operation To ensure continuous, reliable operation, Zonemaster monitors the wiring to the detection devices, manual call points and fire alarm sounders. Failsafe operation In the event of a mains failure, back-up batteries that are housed in the Zonemaster cabinet will continue to power the system. 24hr monitoring option Zonemaster panels can be linked to a Chubb alarm receiving Centre (ARC). This will provide 24hour remote monitoring ensuring rapid response to fire or fault conditions. Ford F 450 Manual.

Fully programmable Easy to programme. Programmable features include nonlatching zones and delayed sounder operation. Www.chubb.co.uk Chubb Fire Chubb Zonemaster 100A & AT Technical Data Zonemaster 102A Power Input Voltage System Voltage Max Battery Size Current Consumption Panel Quiescent (mA) Alarm Current (mA) Detection Zone Quiescent Current (mA) Outputs No.

Chubb Zonemaster 108 Manual